Reference Manual
00809-0100-4530, Rev BA
July 2009
B-13
Rosemount 5300 Series
Explosion Proof
Figure B-12. Approval Labels
Factory Mutual (FM) HART
model
E5 Explosion-Proof for Class I, Division 1, Groups B, C and D.
Dust-Ignition proof for Class II/III, Division 1, Groups E, F and G with
intrinsically safe connections to Class I, II, III, Div 1, Groups B, C, D, E, F
and G.
Temperature code T4.
Ambient temperature limits: -50
°C to + 70 °C.
Seal not required.
Figure B-13. Approval Label
Factory Mutual (FM) Foundation
Fieldbus model
E5 Explosion-Proof for Class I, Division 1, Groups B, C and D.
Dust-Ignition proof for Class II/III, Division 1, Groups E, F and G with
intrinsically safe connections to Class I, II, III, Div 1, Groups B, C, D, E, F
and G.
Temperature code T4.
Ambient temperature limits: -50
°C to + 60°C.
Seal not required.